DATEL ICP232.2-5V 029.361114 Industrial Control Module – Excellent Performance, Easily Coping with Harsh Environments!

The DATEL ICP232.2-5V 029.361114 is a high-isolation DC-DC converter module engineered for critical power supply applications in industrial control, medical equipment, and test instrumentation. Designed to deliver 2.2W of regulated 5V DC output from a 24V DC input, this compact converter provides reinforced isolation (1500 VDC) between input and output circuits, effectively breaking ground loops and suppressing noise in sensitive measurement systems. Its patented switching topology achieves 82% efficiency with low ripple (<50 mVpp), ensuring stable power for analog/digital circuits in electrically noisy environments. Encased in a potted metal shield, the ICP232.2-5V withstands shock/vibration (10g/5g RMS) and operates across -40°C to +85°C without derating. The suffix 029.361114 denotes a specialized variant with extended validation for aerospace and defense applications, including burn-in screening and hermetic sealing for high-altitude operation.

Manufacturer:

Our extensive catalogue, including , is available now for dispatch to the worldwide.
  • Email: sales@runshengdcs.com
  • WhatsApp / Wechat:+86 15383419322
  • Phone:+86 15383419322

Description

The DATEL ICP232.2-5V 029.361114 is a high-isolation DC-DC converter module engineered for critical power supply applications in industrial control, medical equipment, and test instrumentation. Designed to deliver 2.2W of regulated 5V DC output from a 24V DC input, this compact converter provides reinforced isolation (1500 VDC) between input and output circuits, effectively breaking ground loops and suppressing noise in sensitive measurement systems. Its patented switching topology achieves 82% efficiency with low ripple (<50 mVpp), ensuring stable power for analog/digital circuits in electrically noisy environments. Encased in a potted metal shield, the ICP232.2-5V withstands shock/vibration (10g/5g RMS) and operates across -40°C to +85°C without derating. The suffix 029.361114 denotes a specialized variant with extended validation for aerospace and defense applications, including burn-in screening and hermetic sealing for high-altitude operation.

DATEL ICP232.2-5V 029.361114

DATEL ICP232.2-5V 029.361114

Technical Specifications

Parameter Name Parameter Value
Product Model ICP232.2-5V 029.361114
Manufacturer DATEL (Microchip Technology)
Product Type Isolated DC-DC Converter
Input Voltage 18–36 VDC (24V nominal)
Output Voltage 5 VDC ±2%
Output Power 2.2 W (440 mA max)
Isolation Voltage 1500 VDC (input-output)
Efficiency 82% typical
Ripple/Noise <50 mVpp (20MHz BW)
Operating Temperature -40°C to +85°C
Regulation ±0.1% line, ±0.5% load
Short-Circuit Protection Auto-recovery
MTBF >1,000,000 hrs (MIL-HDBK-217F)
Dimensions 25.4 x 25.4 x 10.2 mm (1″ x 1″ x 0.4″)
Certifications EN 50155, DO-160G (variant-specific)

Main Features and Advantages

Ultra-Noise Immunity: Triple-shielded transformer design achieves 100 dB common-mode rejection at 1 MHz – critical for protecting sensitive ADC/DAC circuits in data acquisition systems.

Extended Reliability: Industrial-grade potting compound protects against humidity (100% condensing) and chemical vapors. Gold-plated pins prevent fretting corrosion in high-vibration environments.

Wide Input Flexibility: Operates down to 18V during brownouts and withstands 100V transients (50 ms) per EN 61000-4-5. Reverse polarity protection (-40V for 1 min).

Space-Optimized Design: 1″ x 1″ footprint with through-hole mounting saves PCB space. Low profile (10.2 mm) fits behind instrument panels.

DATEL ICP232.2-5V 029.361114

DATEL ICP232.2-5V 029.361114

Application Field

The DATEL ICP232.2-5V 029.361114 excels in isolation-critical scenarios:

Industrial PLCs: Powering isolated sensor interfaces (RTD/thermocouple) in SIL 2 safety systems

Medical Devices: Isolating patient-connected monitoring circuits (ECG/EEG) per IEC 60601-1

Test & Measurement: Providing clean power to metrology-grade ADCs in calibration equipment

Railway Control: Meeting EN 50155 surge/transient requirements for signaling systems

Avionics: Powering cockpit displays in high-altitude environments (DO-160G Sec 22)

Renewable Energy: Isolating communication circuits in solar/wind inverters

Related Products

ICP231.2-5V: 1W lower-power variant

MEE3S-5: 3W surface-mount converter

HQA300-5: 300W chassis-mount supply

UMK-5: Output filter kit for ultra-low noise

DCH04: 4-channel isolated converter

LCC110: Isolated feedback controller

ADUM5000: Alternative digital isolator IC

Installation and Maintenance

Pre-installation preparation: Verify input polarity before energizing. Include 100 μF electrolytic capacitor within 50 mm of input pins. Maintain 3 mm creepage distance between primary/secondary traces. Use thermal vias for heat dissipation at >70°C ambient.

Maintenance recommendations: Monitor output ripple annually via oscilloscope (>100 MHz BW). Replace if efficiency drops below 75% or isolation resistance measures <100 MΩ at 500 VDC. Avoid ultrasonic cleaning to prevent potting damage.