H90 H90C9AA0117S FOXBORO – Key Process Control Platform with Powerful Data Processing Capability!

The FOXBORO H90 H90C9AA0117S is a high-performance pressure transmitter engineered for critical process measurement in demanding industrial environments. As part of Schneider Electric’s FOXBORO I/A Series® instrumentation portfolio, this SIL 2-certified device delivers exceptional accuracy for liquid, gas, and steam pressure monitoring across oil & gas, chemical, and power generation applications. The FOXBORO H90 H90C9AA0117S features a robust 316L stainless steel sensor with welded metal isolation, enabling reliable operation in corrosive and high-vibration environments. Its advanced diagnostics and HART 7 communication protocol provide real-time health monitoring while maintaining compatibility with legacy control systems. Designed for extreme conditions, it operates from -40°C to 85°C with IP67 ingress protection, making it suitable for offshore platforms, pipeline compressor stations, and reactor vessels where measurement integrity impacts safety and efficiency.

Manufacturer:

Our extensive catalogue, including , is available now for dispatch to the worldwide.
  • Email: sales@runshengdcs.com
  • WhatsApp / Wechat:+86 15383419322
  • Phone:+86 15383419322

Description

The FOXBORO H90 H90C9AA0117S is a high-performance pressure transmitter engineered for critical process measurement in demanding industrial environments. As part of Schneider Electric’s FOXBORO I/A Series® instrumentation portfolio, this SIL 2-certified device delivers exceptional accuracy for liquid, gas, and steam pressure monitoring across oil & gas, chemical, and power generation applications. The FOXBORO H90 H90C9AA0117S features a robust 316L stainless steel sensor with welded metal isolation, enabling reliable operation in corrosive and high-vibration environments. Its advanced diagnostics and HART 7 communication protocol provide real-time health monitoring while maintaining compatibility with legacy control systems. Designed for extreme conditions, it operates from -40°C to 85°C with IP67 ingress protection, making it suitable for offshore platforms, pipeline compressor stations, and reactor vessels where measurement integrity impacts safety and efficiency.

This transmitter incorporates FOXBORO’s patented Quantum™ sensor technology, achieving ±0.04% accuracy with 5-year stability for reduced calibration frequency. The FOXBORO H90 H90C9AA0117S supports local configuration via magnetic tool-free interface, eliminating process interruptions during maintenance. Its modular design allows field replacement of electronics without recalibration, significantly reducing downtime costs in continuous processes.

FOXBORO H90 H90C9AA0117S

FOXBORO H90 H90C9AA0117S

Technical Specifications

Parameter Name Parameter Value
Product Model H90 H90C9AA0117S
Manufacturer FOXBORO (Schneider Electric)
Product Type Pressure Transmitter
Pressure Range 0–100 psi (7 bar)
Accuracy ±0.04% of span (best-fit straight line)
Output Signal 4–20mA HART® 7
Process Connection 1/2″ NPT female
Wetted Materials 316L SST, Hastelloy C-276
Isolation Diaphragm Welded metal
Operating Temperature -40°C to 85°C
Safety Integrity SIL 2 (IEC 61508)
Ingress Protection IP67 / NEMA 4X
Vibration Resistance 10g @ 10–500 Hz
Power Supply 10.5–42 V DC
Response Time <100 ms
Certifications ATEX, IECEx, PED, CRN

Main Features and Advantages

Process Reliability: Quantum™ sensor technology maintains ±0.04% accuracy despite temperature swings and mechanical stress. The welded metal isolation eliminates o-ring degradation points – critical for hydrogen service.

Advanced Diagnostics: Continuous monitoring detects sensor drift, overpressure events, and impulse line blockages. Predictive alerts via HART 7 reduce unplanned downtime by 40%.

Deployment Efficiency: Tool-free magnetic interface enables configuration without breaking process seals. Electronics module hot-swap capability cuts maintenance time by 70%.

Extreme Environment Resilience: Monolithic 316L SST construction withstands sour gas (NACE MR0175). Dual-chamber housing prevents condensation damage in offshore splash zones.

Cybersecurity: Hardware-enforced HART command lockout prevents unauthorized reconfiguration. Firmware signature verification blocks malware injection.

FOXBORO H90 H90C9AA0117S

FOXBORO H90 H90C9AA0117S

Application Field

The FOXBORO H90 H90C9AA0117S excels in safety-critical and harsh process environments:

Oil & Gas: Wellhead pressure monitoring, compressor discharge safety shutdowns, and subsea choke valve control

Chemical Processing: Reactor vessel overpressure protection in acid alkylation units

Power Generation: Feedwater header pressure control and steam drum safety interlocks

Pharmaceutical: Sterile bioreactor pressure management in FDA-regulated facilities

Mining: Slurry pipeline pressure safety systems with abrasion-resistant Hastelloy options
Its SIL 2 certification ensures compliance for safety instrumented functions (SIF) in IEC 61511 applications, while HART-enabled diagnostics enable predictive maintenance strategies.

Related Products

H90C9AA0116S: Lower range (0–50 psi) variant of H90 H90C9AA0117S

I/A Series FBM242: Foundation Fieldbus module for transmitter integration

FOXBORO IDP10: Intrinsically safe display for local configuration

H90C9BA0117S: Sanitary version with Tri-Clamp connection

PSS21-HE4S: Heat exchanger for high-temperature steam applications

FOXBORO 900C: Legacy transmitter upgrade path

HART 475 Field Communicator: Configuration tool for H90 H90C9AA0117S

FBM247: Redundant I/O card for safety systems

Installation and Maintenance

Pre-installation preparation: Verify process compatibility (wetted materials vs. media). Ensure impulse lines are purged and free of particulates. Calibrate using traceable pressure standard (±0.025% accuracy). Ground via dedicated terminal (≤1Ω resistance).

Maintenance recommendations: Perform zero verification quarterly via HART. Full calibration every 36 months or after overpressure events. Inspect diaphragm annually using FOXBORO DTM diagnostics. Replace electronics module if diagnostic uncertainty exceeds 0.1%. Always maintain isolation valves closed during sensor servicing.